Temperature controlled continuous flow gas hot water system with status monitor for external residential applications. Flangeless case design and pipe cover for a more modern look.
Units are sold with a pipe cover. Two models:
– XR20+ (REU-VM2024WD)
– XR26+ (REU-VM2630WD)
Suitable for external mains and medium pressure residential systems. Hard or acidic water will need to be treated in order to use this product.
Fitted as standard. Frost protection operates automatically, as long as the appliance is connected to the electrical power supply, by activating when the temperature inside the unit drops below 3.5 ºC, and turns off once the temperature inside the unit reaches 7 °C.
Ignition system
Direct electronic ignition
Injector sizes XR20+
NG: 0.85, 1.30
LPG: 0.70, 1.05
Injector sizes XR26+
NG: 1.0, 1.55
LPG: 0.70, 1.05
Line pressure min.
NG: 1.13 kPa, LPG: 2.75 kPa
Line pressure max.
3.5 kPa, maximum standing pressure under abnormal intermittent conditions is 5.0 kPa.
In the case of commercial metering, i.e. 35-37 kPa coming in, there may be a requirement to regulate the incoming pressure down.
Power consumption
Model
NG
LPG
Standby
Automatic frost protection
XR20+
46 W
51 W
2 W
72 W
XR26+
52 W
57 W
2 W
72 W
Pressure relief
Valve opens at 2060 kPa and closes at 1470 kPa
Noise level
50 dB(A)
NOx af
XR20+ = 42 ppm,
XR26+ = 52 ppm
Safety devices
Flame failure, boil-dry protection, overheat protection, fusible link, pressure relief valve, and combustion fan RPM check