Suitable for
Living rooms and open plan areas. The versatile power flue system makes for easy installation in almost any living space, including bedrooms.
Heating areas (up to)
- Upper North Island 125 m²
- Central and lower North Island 111 m²
- South Island 82 m²
Gas type
Available for Natural Gas or LPG, specify gas type at time of purchase.
General clearances around the Evolve when operating
The appliance must not be installed where curtains or other combustible material (coffee tables, couches etc.) could come into contact with it. In some cases curtains may need restraining.

Energy Star Rating
Data plate |
Located inside the appliance, upper right hand side. |
Convection fan |
3-speed fan. Heat is distributed from the top of the appliance. |
Gas connection |
½ " BSP, the gas supply terminates inside the heater—lower left hand side of the appliance. |
Ignition |
Continuous spark electronic ignition |
Noise level |
37-45 dB(A) |
Power flue |
Inner 50 mm, outer 70-80 mm. Appliance must be installed with a Rinnai flue system. |
Power consumption and electrical supply |
High 90 W, standby < 8 W. This heater has a 1.5 m power cord with a 3-pin plug supplied. The power cord passes through a slot in the back right hand corner of the appliance. |
Safety devices |
Flame failure sensing system, pressure relief, overheat safety switch, air temperature sensor, thermal fuse, overcurrent fuse, and spark detector. |
Temperature control |
Thermostatic, temperature control range 16-26 °C. |
Weight |
75 kg |
Compliance |
Supplier declaration of compliance: Declaration number - 1724420162 |
Market release |
March 2016 |
Discontinued |
March 2018, superseded by the Evolve 952 with simple remote |
* kW output and energy star rating will vary according to gas type and flue configuration